Please note that all quotes shown here might vary a few mm/cms
once the technical drawings will be finalised.
Kitchen/Dining & Living Unit, Plan
>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, South Side
On this side no cuts and welding to be done, the openings are the original containers doors, they will be doubled with inside opening glass doors.
Two glass doors, H 2576mm x W 2118mm = TL m2 10,92
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, South/West View
>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, South Side
On this side no cuts and welding to be done, the openings are the original containers doors, they will be doubled with inside opening glass doors.
Two glass doors, H 2576mm x W 2118mm = TL m2 10,92
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, South/West View
>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, West Side
K/D & L Unit, West Side Detail
1 Door 2576mm x 1934mm = side wall cut 9020mm
2 Fixed Windows, each 2576mm x 650mm = side wall cut 12904mm
Total cut line on this side wall is 21924mm
Corten Steel Plates 6mm thick (doors and windows frames)
Along the doors sides and upper cuts we will weld the Corten Steel Plates, NOT on the bottom side/floor level.
Therefore we will have plates in number and sizes as follows:
6x 2576mm x 450mm = m2 6,96
2x 650mm x 450mm = m2 0,58
1x 1934mm x 450 = m2 0,87
Total weld line on this side wall is 18690mm and the Corten plates will be in total m2 8,41.
One glass door, H 2576 x W 1934mm
and two glass doors, each H 2576mm x W 650mm = TL m2 8,33
One glass door, H 2576 x W 1934mm
and two glass doors, each H 2576mm x W 650mm = TL m2 8,33
This side after one door and two fixed windows cut
remains with four portions of wall
1x 2576mm x 4586mm = total m2 11,81
1x 2576mm x 586mm = m2 1,51
1x 2576mm x 2200mm = m2 5,67
1x 2576mm x 1546mm = m2 3,98
1x 2576mm x 2200mm = m2 5,67
1x 2576mm x 1546mm = m2 3,98
Total m2 22,97
this figure is to be taken in consideration
when quoting the indoor wall insulation and finishing
and outdoor "Costanera" skin.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, North/East View
K/D & L Unit, North Side
2 Windows, each 500mm x 1118mm = side wall cut 6472mm
Total cut line on this side wall is 6472mm
Corten Steel Plates 6mm thick (doors and windows frames)
All along the windows sides we will weld the Corten Steel Plates
Therefore we will have plates in number and sizes as follows:
4x 500mm x 450mm = m2 0,9
4x 1118mm x 450mm = m2 2,12
Total weld line on this side wall is 6472mm and the Corten plates will be in total m2 2,02.
Two glass windows, each H 500mm x W 1118mm = TL m2 1,12
Two glass windows, each H 500mm x W 1118mm = TL m2 1,12
This side after two windows cut
remains with two portions of wall
2x 2576mm x 2118mm (minus the two windows surface) = total m2 10,92
Total m2 10,92
this figure is to be taken in consideration
when quoting the indoor wall insulation+finishing
and outdoor "Costanera" skin.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, East Side
1 Window (left in the pic), 900mm x 3500mm = side wall cut 8800mm
1 Window (right in the pic), 900mm x 3000mm = side wall cut 7800mm
Total cut line on this side wall is 16600mm
Corten Steel Plates 6mm thick (doors and windows frames)
All along the windows sides we will weld the Corten Steel Plates
Therefore we will have plates in number and sizes as follows:
4x 900mm x 450mm = m2 1,62
2x 3500mm x 450mm = m2 3,15
2x 3000mm x 450mm = m2 2,7
Total weld line on this side wall is 16600mm and the Corten plates will be in total m2 7,47.
Two glass windows,
H 900mm x W 3500mm
H 900mm x W 3000mm = TL m2 5,85
Two glass windows,
H 900mm x W 3500mm
H 900mm x W 3000mm = TL m2 5,85
This side after two windows cut
will have a size of
2576mm x 11872mm (minus the two windows surface) = total m2 24,73
Total m2 24,73
this figure is to be taken in consideration
when quoting the indoor wall insulation+finishing
and outdoor "Costanera" skin.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, inside wall opening cut.
One opening cut on the inside walls
2x each wall side 2576mm x 3500mm = TL 12152mm
Corten Steel Plates to seal the cutting line to be designed.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, inside walls detail.
This unit will have one inside wall+door for each side
left, to the technical and storage area
right, to the WC
Total inside walls surface = m2 7,13
K/D & L Unit with Roof, South West View
K/D & L Unit with Roof, South View
K/D & L Unit, inside wall opening cut.
One opening cut on the inside walls
2x each wall side 2576mm x 3500mm = TL 12152mm
Corten Steel Plates to seal the cutting line to be designed.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit, inside walls detail.
This unit will have one inside wall+door for each side
left, to the technical and storage area
right, to the WC
Total inside walls surface = m2 7,13
>>>>>>>>>>>>>>>>>>>>>>>>>
K/D & L Unit with Roof
K/D & L Unit with Roof, South View
K/D & L Unit with Roof, South View